Inhouse product
Do you face challenges measuring flows that are corrosive, abrasive, or have low conductivity? Are slurry noise and electrode coating compromising your data? For over half a century, Yokogawa's magnetic flowmeters have set the industry standard by consistently introducing innovative specifications. From the world's first dual-frequency excitation method to capacitance-based sensing and the new "Total Insight" concept, Yokogawa delivers high-performance, high-quality flow measurement solutions for the most demanding applications in chemical, pulp & paper, water, and other industries.
Gain reliable flow data with intelligent features that directly address common industrial pain points.
Conquer Slurry Noise and Unstable Flow: Traditional magmeters struggle with the electrical noise generated by high-concentration slurries or fluids with solid particles. Yokogawa's dual-frequency excitation method, first introduced in the ADMAG AM series and refined in models like the ADMAG AXR, provides exceptional stability and accuracy by switching between low and high-frequency excitation. This ensures reliable measurement even under challenging flow conditions where slurry noise would cause other meters to fail.
Measure Previously "Impossible" Fluids: Adhesive fluids and those with very low conductivity (down to 0.01 µS/cm) can render conventional wetted-electrode meters useless due to coating or insufficient signal. The ADMAG CA Series solves this with a capacitance-type (non-wetted electrode) design. This innovative magnetic flowmeter measures flow without the electrodes contacting the fluid, ensuring stable, accurate readings for insulator-adhesive fluids, high-concentration slurries, and even recycled oil containing water, as highlighted in their application notes.
Gain Total Insight with Advanced Diagnostics: Don't just measure flow; understand the health of your process and instrument. The latest ADMAG Total Insight series (AXG/AXW) is built around a concept of supporting the entire product lifecycle. It features abundant diagnostic functions, including flow noise diagnosis, low conductivity detection, electrode insulation deterioration monitoring, and electrode adhesion detection. These tools enable predictive maintenance, prevent unplanned downtime, and ensure long-term measurement reliability.
High Accuracy Across a Wide Range: Achieve the precision you need for control and custody transfer. The ADMAG Total Insight series delivers a standard specification accuracy of ±0.3% of reading (ADMAG AXG) , while the ADMAG AXW offers ±0.35% for larger line sizes up to 1800 mm. The specialized CA Series provides reliable measurement with ±0.5% accuracy.
Engineered for longevity, precision, and seamless integration:
Multiple Technology Platforms: Choose the right tool for the job.
ADMAG Total Insight (AXG/AXW): The successor to ADMAG AXF, offering 4-wire high performance with advanced diagnostics and a wide range of communication protocols (HART 7, BRAIN, Modbus, FOUNDATION Fieldbus, PROFIBUS PA, EtherNet/IP).
ADMAG CA Series: The solution for difficult fluids, featuring non-wetted capacitance electrodes and the ability to measure from just 0.01 µS/cm.
ADMAG AXR: The world's first 2-wire magnetic flowmeter with dual-frequency excitation, achieving 0.5% accuracy and excellent noise immunity with low power consumption.
Extensive Sizing & Liner Options: Available in sizes from 2.5 mm to 1800 mm with various liner materials (including high-purity ceramic for thermal shock resistance) to match your specific process and fluid compatibility requirements.
Proven Reliability in Harsh Environments: Backed by decades of field-proven experience in industries like chlor-alkali, chemical recovery, and mining, ensuring long-term performance in corrosive and abrasive applications.
Proactive Health Verification: Use the FSA130 Verification Tool (with FieldMate) to perform health checks, diagnostics, and reporting for your ADMAG TI and CA Series meters, ensuring confidence in their performance over time.
Technology & Measurement Principle
Principle: Faraday's Law of Electromagnetic Induction
Key Technologies: Dual-Frequency Excitation, Capacitance-type (Non-wetted electrode), Total Insight concept
Model Series Overview
Diagnostic Functions (ADMAG TI Series)
Application Diagnostics: Flow Noise, Low Conductivity, Electrode Insulation Deterioration, Electrode Adhesion Detection
Integrity Checks: Sensor Empty Check, Wiring Connection Diagnosis
Verification: Built-in / Standard / Enhanced Verification options
Outputs & Communication
Wiring: Primarily 4-wire systems (ADMAG AXR is 2-wire)
Communication Protocols: HART 7, BRAIN, Modbus, FOUNDATION Fieldbus, PROFIBUS PA, EtherNet/IP (varies by series)
Display: Dot matrix display for excellent visibility (CA Series, TI Series)
Application Suitability (General Guide)
Whether you are dealing with abrasive mining slurries, insulating adhesive chemicals, or need high accuracy for water custody transfer, Yokogawa has a magnetic flowmeter designed for your success.
Optimum Solution is a leading supplier of laboratory equipment, analytical instruments, and process control solutions in Bangladesh. Since our inception, we have built a strong presence in the industry, serving research labs, universities, pharmaceutical companies, and quality control laboratories nationwide. Through continuous dedication to improving our products and services, Optimum Solution has earned the trust and loyalty of our valued clients.