Inhouse product
The Biological Safety Cabinet is engineered to eliminate these risks. As a cornerstone of the Biological Safety Cabinet series, this Class II Type B2 unit is built for microbiological research, pharmaceutical development, clinical diagnostics, and tissue culture laboratories that require uncompromising total-exhaust containment. This Biological Safety Cabinet provides a reliable, validated work environment with 100% exhaust airflow, U15 ULPA supply filtration, and H14 HEPA exhaust filtration, so that all air passing through the work zone is discharged from the building rather than recirculated. We understand that in your line of work, total-exhaust containment reliability is not just a feature—it is a safety necessity.
Here is a detailed breakdown of the technical capabilities for the Biological Safety Cabinet. Our models are designed to meet rigorous international biosafety standards including YY0569 and NSF49.
Model/Part Number: PF-B3
Nominal Size: 3 feet / 1000 mm
External Dimensions (W×D×H): 1100×800×2040 mm
Internal Dimensions (W×D×H): 1000×600×600 mm
Usable Working Area: 0.6 m²
Net Weight: 250 kg
Rated Power: 800W
Rated Current: 5A
Power Consumption: 0.7 kWh/h
Inflow Air Volume: 396 m³
Downflow Air Volume: 662 m³
Exhaust Air Volume: 1058 m³
Noise Level: <60 dB(A)
Model/Part Number: PF-B4
Nominal Size: 4 feet / 1300 mm
External Dimensions (W×D×H): 1400×800×2040 mm
Internal Dimensions (W×D×H): 1300×600×600 mm
Usable Working Area: 0.78 m²
Net Weight: 280 kg
Rated Power: 900W
Rated Current: 5.5A
Power Consumption: 0.8 kWh/h
Inflow Air Volume: 515 m³
Downflow Air Volume: 861 m³
Exhaust Air Volume: 1376 m³
Noise Level: <61 dB(A)
Model/Part Number: PF-B5
Nominal Size: 5 feet / 1600 mm
External Dimensions (W×D×H): 1700×800×2040 mm
Internal Dimensions (W×D×H): 1600×600×600 mm
Usable Working Area: 0.96 m²
Net Weight: 320 kg
Rated Power: 1000W
Rated Current: 6A
Power Consumption: 0.9 kWh/h
Inflow Air Volume: 634 m³
Downflow Air Volume: 994 m³
Exhaust Air Volume: 1628 m³
Noise Level: <63 dB(A)
Type: Class II, Type B2
Airflow Pattern: 100% exhaust
Exhaust Direction: Top exhaust
Average Inflow Velocity: 0.55 m/s
Average Downflow Velocity: 0.32 m/s (0.30 m/s on PF-B5)
Blower: Advanced DC ECM blower with CAV and CPAS technology
Filter, Downflow: U15 ULPA, ≥99.9995% @ MPPS, EN1822, with filter life indicator alert
Filter, Exhaust: H14 HEPA, ≥99.995% @ MPPS, EN1822
Cleanliness Grade: ISO Class 4
Operator Protection: Total colony in impaction sampler ≤10 CFU; slit type sampler ≤5 CFU
Product Protection: Total colony in culture dish ≤5 CFU
Cross-Contamination Protection: Total colony in culture dish ≤2 CFU
Front Sash: Motorized electric sash operated with touch screen, foot switch, or remote controller
Working Table Height: 750/800/850/900/950 mm adjustable
Working Height of Front Window: 200 mm
Maximum Opening Height of Front Window: 480 mm
Display & Control: 7-inch touchscreen with WiseFlow control system, ECO mode, ambient temperature and humidity display, UV and filter working time display, cabinet ON/OFF timer, UV timer, password protection, RS485 port
Alarm Type: Visible and audible alarm for inflow velocity, downflow velocity, sash height limit, high filter resistance, fan failure, and filter life alert
Working Tray Material: SUS304
Inner Walls Material: SUS304
Main Body Material: Spray-coated steel
Front Sash Glass: Tempered glass, UV-proof, 6mm
Stand: Detachable with adjustable height, 4 leveling feet, 4 casters
Power Supply: 220V/50Hz, 220V/60Hz, 110V/60Hz
Compliance: YY0569, NSF49
Standard Accessories included:
Biological safety cabinet base unit with Class II Type B2 configuration
U15 ULPA downflow supply filter with filter life indicator
H14 HEPA exhaust filter
Advanced DC ECM blower with CAV and CPAS
7-inch touchscreen WiseFlow control system
Motorized electric front sash with foot switch
SUS304 stainless steel working tray and inner walls
6mm tempered UV-proof front sash glass
Detachable adjustable-height stand with 4 leveling feet and 4 casters
LED lamp (1 pc)
UV lamp (1 pc)
Receptacles (2 pcs, total 880W, 4A)
Drain valve and water collection container under work tray
Raised arm rest
Operation manual
Items Excluded:
External exhaust blower (required for installation, available separately)
Vacuum, gas, and water valves (optional)
Arm rest (optional on some configurations)
IV bar (optional)
Calibration certificate (available upon request)
Extended warranty (available for purchase)
Filter replacement (available separately)
Pre-installation requirement:
A stable, level floor with sufficient load-bearing capacity
A dedicated power outlet matching the unit's specifications (220V/50Hz, 220V/60Hz, or 110V/60Hz)
External exhaust blower and ductwork to route exhaust air out of the building, sized to match the model's exhaust air volume
Adequate clearance around the unit for access and service
Building HVAC capacity to accommodate the exhaust volume
Operator training on standard biosafety cabinet procedures and certification is recommended
Our Biological Safety Cabinet is more than just a piece of equipment; it is a solution designed to address the real-world challenges you face daily. We have focused on core features that deliver tangible benefits, enhancing your lab's safety and the reliability of your containment work.
100% Total-Exhaust Containment: All air passing through the work zone is discharged from the building through the exhaust filter, with no recirculation into the room. This directly solves the common pain point of chemical vapor and radionuclide recirculation, giving you confidence when handling volatile or hazardous materials. For more information on our full range of laboratory instruments, visit our website at Optimum Solution.
Dual High-Efficiency Filtration: A U15 ULPA downflow supply filter (≥99.9995% @ MPPS) delivers ISO Class 4 cleanliness, while the H14 HEPA exhaust filter (≥99.995% @ MPPS) protects the environment, both conforming to EN1822. This engineering excellence reflects the manufacturer's commitment to biosafety standards, and you can view the product page on the manufacturer's site for additional technical resources and application notes.
Energy-Efficient DC ECM Blower: The advanced DC ECM blower with Constant Air Volume and Constant Pressure Apheresis System technology maintains safe airflow as filter resistance changes, while ECO mode shortens airflow recovery time and lowers power consumption.
Motorized WiseSash Design: The electric sash operates by touch screen, foot switch, or remote controller, with an independent manual sash system that can be shut down during power failure and UV-proof glass protecting people during disinfection.
WiseClean and WisePort Convenience: The front window lowers for cleaning, the work tray lifts and is supported by a rod for access beneath the tray area, and WisePort fittings on both side walls allow flexible installation of valves and pipelines.
Comprehensive Smart Monitoring: The 7-inch touchscreen displays downflow velocity, inflow velocity, differential pressure, ambient temperature and humidity, UV working time, filter working time, and filter life percentage, with dual UV timers for flexible shift matching.
Full Alarm Coverage: Visible and audible alarms for inflow velocity, downflow velocity, sash height limit, high filter resistance, fan failure, and filter life alert keep operators informed of any condition requiring attention.
We know the frustrations that come with daily biosafety cabinet operation. The Biological Safety Cabinet is built to eliminate them.
Struggling with recirculated vapors from chemical or radionuclide work? The 100% exhaust airflow pattern discharges all work zone air outside the building through the HEPA exhaust filter, eliminating recirculation risk.
Concerned about filter condition and replacement timing? The WiseFlow control system displays filter life percentage and working time, triggering alarms for high resistance and filter life so you always know your cabinet is safe to operate.
Tired of awkward sash handling during loading and cleaning? The motorized sash operates by touch screen, foot switch, or remote, the front window lowers for cleaning, and the work tray lifts for access beneath the tray area.
Need compliance with recognized standards? The cabinet meets YY0569 and NSF49, with operator, product, and cross-contamination protection verified against accepted microbiological test methods. For more information on NSF/ANSI 49 biosafety cabinet standards, visit the NSF International website.
By choosing this Biological Safety Cabinet, you are investing in a dependable partner for your lab's daily operations, designed to deliver total-exhaust containment safety and reliability where it matters most.
We provide a 1-year manufacturer’s warranty covering parts and labor. Technical support, installation assistance, and operational training are also available. Replacement parts and consumables are available throughout the product’s service life.
Request a Quotation or Technical Datasheet: Contact us for more information, customized configurations, and solutions tailored to your specific requirements. You can also reach out through Optimum Solution to plan your external exhaust blower and ductwork, confirm valve and WisePort options, and select the cabinet size that best fits your laboratory workflow.
Optimum Solution is a leading supplier of laboratory equipment, analytical instruments, and process control solutions in Bangladesh. Since our inception, we have built a strong presence in the industry, serving research labs, universities, pharmaceutical companies, and quality control laboratories nationwide. Through continuous dedication to improving our products and services, Optimum Solution has earned the trust and loyalty of our valued clients.