Precise, High Throughput Nucleic Acid Purification for Modern Molecular Labs

Struggling with inconsistent DNA/RNA yields, cross‑contamination risks, or manual extraction bottlenecks? The fully automated MASTER SCIENCE MSBKHS96SWISS nucleic extraction system eliminates these frustrations. This paramagnetic particle‑based extractor processes up to 96 samples per run, delivering ≥98% magnetic bead recovery with outstanding intra‑assay repeatability. Whether you run qPCR, NGS, or forensic analysis, the MSBKHS96SWISS Automatic Nucleic Acid Extraction System fits seamlessly into your workflow.

Below you will find the exact technical specifications that guarantee reliable performance in clinical, research, and diagnostic laboratories.


Technical Specifications (Model MSBKHS96SWISS)

  • Model Number: MSBKHS96SWISS

  • Nucleic Acid Extraction Method: Paramagnetic particle (magnetic bead) method

  • Sample Capacity: 96 wells per run

  • Sample Volume Range: 20–1000µl

  • Extraction Time: 11 to 60 minutes (programmable)

  • Magnetic Bead Recovery: ≥98%

  • Magnetic Flux of Bar: ≥4500 Gauss (3000‑6000 Gs with interchangeable rods)

  • Operating Temperature Range: Room temperature to 105°C

  • Temperature Accuracy: ±0.1°C

  • Shock/Vibration Function: Yes (3‑step adjustable vertical & horizontal oscillation)

  • Temperature Control Modes: Independent heating on 8 plate positions; active cooling to room temperature

  • Sample Protection: Power‑on self‑check, power‑off protection, high‑temperature alarm, over‑temperature protection

  • Disinfection Method: UV light (selectable duration)

  • Contamination Control: Built‑in airflow channel + HEPA high‑efficiency filter (Grade 11)

  • Safety Door Design: Instrument operation pauses immediately when door is opened

  • Operating System: Windows OS

  • Barcode Scanning: Optional

  • Program Storage: >1000 stored protocols (expandable to >500 with PurifierPro software)

  • Interface: USB port (Ethernet optional)

  • Power Supply: AC100–240V, 50Hz/60Hz

  • Physical Dimensions (Instrument): 685 × 600 × 390mm (net); 980 × 575 × 725mm (bare unit)

  • Package Size (W×D×H): 940 × 710 × 910mm (standard export carton); 1138 × 733 × 988mm (optional)

  • Net Weight: 40kg

  • Gross Weight: 110kg (130kg for export package)


H2: Key Benefits – Faster, Safer, and More Consistent Extractions

Integrating the MASTER SCIENCE Automatic Nucleic Acid Extraction System into your daily operations delivers immediate improvements across three critical areas:

Lab efficiency – Run 96 samples in as little as 11 minutes. The integrated heating and shaking modules work simultaneously, cutting total extraction time compared to sequential systems. Pre‑programmed protocols eliminate manual pipetting steps, freeing your researchers for higher‑value tasks.

Accuracy and repeatability – With ≥98% magnetic bead recovery and temperature control accurate to 0.1°C, the MSBKHS96SWISS Nucleic Acid Purification System ensures low inter‑well variation (≤3% CV). This means identical yields whether you run samples in column 1 or column 12 – critical for quantitative downstream assays.

Operator and sample safety – A HEPA filter captures 99.97% of aerosol particles, while UV disinfection runs between batches. The safety door instantly halts all moving parts when opened. Your team works without exposure risk, and your samples remain free from cross‑contamination.


H2: Solving Common Laboratory Pain Points

Pain point: Variable yields and wasted repeats
Manual extraction or poorly calibrated instruments produce inconsistent DNA/RNA quantities, forcing costly re‑extractions. The magnetic bead‑based MSBKHS96SWISS extraction instrument uses closed‑loop temperature control and programmable mixing profiles. Every run follows exactly the same parameters, so you trust your results the first time.

Pain point: Cross‑contamination ruining sensitive assays
Aerosol carryover between wells or batches invalidates PCR and NGS data. This system features a physically isolated airflow channel with an Grade 11 HEPA filter, plus a UV disinfection lamp that runs independently. The MASTER SCIENCE MSBKHS96SWISS High Throughput Extractor actively prevents contamination at the source – not just as an afterthought.

Pain point: Time‑consuming manual protocols
Hand‑loading 96 samples with multiple wash steps ties up skilled staff for hours. The fully automated workflow from lysis to elution requires only that you place your plate and press “start”. The MSBKHS96SWISS laboratory nucleic acid extractor runs unattended, so your team focuses on analysis, not pipetting.

Pain point: Inflexible platforms that lock you into one reagent brand
Many extraction systems force you to buy proprietary kits. The open‑platform MASTER SCIENCE MSBKHS96SWISS system works with any paramagnetic bead‑based kit – both pre‑filled cartridges and bulk reagents. Switch suppliers or optimise your own protocol without hardware changes.


H3: Feature Spotlight – What Makes This Extractor Unique

  • Dual‑mode mixing – Choose vertical oscillation (3 levels) or horizontal shaking (3 levels) to match your sample type, from viscous blood to homogenised tissue.

  • 8 independent heating zones – Different wells can run at different lysis/elution temperatures simultaneously, perfect for protocol development.

  • 96/24 universal magnetic rod – Exchange the 96‑pin head for a 24‑pin version on the same instrument. No second machine required for smaller batch sizes.

  • Intelligent cyclic magnetic capture – Residual magnetic beads in any reaction system drop below 0.5%, even with high‑volume eluates.

  • Shock‑absorbing aluminium base – Reduces operational noise and increases mixing amplitude for better bead binding efficiency.

  • Ethernet remote control (optional) – Monitor and control runs from your office computer or across a laboratory network.


H4: Compatible Sample Types and Downstream Applications

The MSBKHS96SWISS handles a remarkably wide range of biological materials: whole blood, serum, plasma, viruses, tissues (animal & plant), fungi, bacteria, cultured cells, swabs (throat, anal, reproductive tract), stool, dried blood spots, sputum, urine, and exfoliated cells.

Purified nucleic acids are directly compatible with:

  • qPCR / qRT‑PCR

  • Next‑generation sequencing (NGS)

  • Microarray analysis

  • Forensic STR typing

  • Infectious disease monitoring (HBV, HCV, HPV, HIV, TB, COVID‑19)


H2: Ready to Automate Your Nucleic Acid Extraction?

Stop compromising on yield consistency or exposing your team to manual handling risks. The MSBKHS96SWISS Automatic Nucleic Acid Extraction System delivers high throughput, regulatory‑ready documentation, and true open‑platform flexibility – all at a competitive price point. Order model MSBKHS96SWISS today and receive the full accessory package including the 96‑pin magnetic rod, HEPA filter, UV lamp, and starter protocol library.

Contact us for a custom quotation, on‑site demo, or assistance with IQ/OQ validation documents for GMP/compliance laboratories.


Frequently Bought Products

Optimum Solution– Laboratory & Analytical Instruments Supplier in Bangladesh

Optimum Solution is a leading supplier of laboratory equipment, analytical instruments, and process control solutions in Bangladesh. Since our inception, we have built a strong presence in the industry, serving research labs, universities, pharmaceutical companies, and quality control laboratories nationwide. Through continuous dedication to improving our products and services, Optimum Solution has earned the trust and loyalty of our valued clients.

All categories
Flash Sale
Todays Deal